Red zone less than 15% reserve margin It also provides net generation at the prime mover level for all plants. BANC contracts with SMUD for operations of the Balancing Authority. [7] Frequently the same utility plays multiple roles, for example, CAISO, in addition to being an independent system operator, is also operating under the name RC West as a reliability coordinator for 42 balancing authorities and transmission operators in the Western interconnection. It matches generation with load and maintains consistent electric frequency of the grid, even during extreme weather conditions or natural disasters. PDF WECC-0115 BAL-002-WECC-3 - Contingency Reserve - Exhibit A - Final The order requires that Federal agencies report their building information in EPAs Portfolio Manager which uses eGRID to estimate emission reductions. [3], A meter on a tie-line is shared between the two BAs interconnected by this line. International energy information, including overviews, rankings, data, and analyses. Crude oil, gasoline, heating oil, diesel, propane, and other liquids including biofuels and natural gas liquids. A balancing authority (BA) is an entity in the US electric system (as well as in parts of Canada and Mexico) that is responsible for grid balancing: resource planning and unit commitment ahead of time, maintenance of the load-interchange-generation balance within a balancing authority area (also known as a control area) and support for real-time load-frequency control. eGRID2012 and subsequent editions (and associated materials) reference previous eGRID editions using the new naming convention and the files available for download from the website use the new naming convention; however, the content within the previous editions of eGRID, such as the technical support documents, has not been revised. 2. Die technische Speicherung oder der Zugriff ist erforderlich, um Nutzerprofile zu erstellen, um Werbung zu versenden oder um den Nutzer auf einer Website oder ber mehrere Websites hinweg zu hnlichen Marketingzwecken zu verfolgen. BANC - Balancing Authority of Northern California BCHA - British Columbia Hydro Authority BPAT - Bonneville Power Administration-Transmission CFE - Comision Federal de Electricidad CHPD - PUD No. Wenn du deine Zustimmung nicht erteilst oder zurckziehst, knnen bestimmte Merkmale und Funktionen beeintrchtigt werden. The output emission rates (e.g. EIA provides net generation at the unit level for a subset of plants in the United States. The net generation in the Generator fileis based on unit-level generation data whereavailable. ISO New England Inc. Personalized content and ads can also include more relevant results, recommendations, and tailored ads based on past activity from this browser, like previous Google searches. PDF 2022 Loads and Resources Data Collection Manual - NorthernGrid Monthly and yearly energy forecasts, analysis of energy topics, financial analysis, congressional reports. This is particularly true for the emission rates by fuel type, such as the emission rates for oil. Extra-high-voltage connections between individual utilities permit the transfer of electrical energy from one part of the network to another. Hub Map - WECC Power & Gas. The national-fuel and state-fuel content average, calculated from EIA-923 Schedule 3A, was updated. CAISO manages 80 percent of the load in California and a small portion of Nevada.The main balancing authorities in California are:CAISO - California Independent System OperatorBANC -Balancing Authority of Northern CaliforniaLADWP - Los Angeles Department of Water & PowerIID - Imperial Irrigation DistrictTID - Turlock Irrigation DistrictWALC -Western Area Power Administration, Lower ColoradoPacifiCorp WestNV Energy, California Electric Balancing Authority Areas, https://cecgis-caenergy.opendata.arcgis.com/maps/CAEnergy::california-electric-balancing-authority-areas, {"type": "Polygon", "coordinates": [[[-124.4096,32.5263],[-124.4096,41.9050],[-112.9475,41.9050],[-112.9475,32.5263],[-124.4096,32.5263]]]}. Western Interconnection-Wide Planning Facilitator- WECC provides planning functions (transmission planning and integration of resources) and policy-related functions as requested by members. eGRID2014 and subsequent eGRID editions use only EIA data, as well as a new formula (as described above). Transmission Services - PacifiCorp Proposed regional Reliability Standard BAL-002-WECC-3 applies to balancing authorities and reserve sharing groups in the WECC Region, and it specifies the quantity and types of contingency reserve required to ensure reliability under normal and abnormal conditions. State energy information, including overviews, rankings, data, and analyses. Other EPA emission data sources also provide data on emissions associated with electricity generation. Your input and feedback is greatly appreciated. For a small number of plants, we also use the plants NERC Assessment Area. PDF Regional Entities Page 1 of 2 - Nuclear Regulatory Commission eGRID is also used by other Federal Government agencies such as Oak Ridge National Laboratory (ORNL) for their Combined Heat and Power and Emissions Savings Calculator, the National Energy Technology Laboratory (NETL) for their sponsored Distributed National Carbon Sequestration Database and Geographic Information System (NATCARB), and the National Renewable Energy Laboratory (NREL) for their micropower distributed generation optimization model named HOMER. How has the methodology for estimating methane (CH. 4.1 Balancing Authority 5. More>>, NERC Balancing Authority Areas (As of October 2019). WECC Daily Status Report 2023-04-27 Author: Paull, Evan Last modified by: Paull, Evan Created Date: 4/27/2023 12:57:31 PM Other titles: Sheet1 Map . XLSX www.wecc.org PDF Western Area Power Administration -Rocky Mountain Region the Eastern Interconnected System (from the Atlantic ocean to the Rocky Mountain States), the Western Interconnected System (for States west of the Rocky Mountains), and. hb``a``f`` Assets for Public Service Company of Colorado - PSCO - WECC Power & Gas Data years after 2016 are not included in the ZIP file but are available for download from the webpage. If a Balancing Authority does not have the necessary reserves, they will need to import from a neighboring Balancing Authority or increase the resources available to meet the demand. Comprehensive data summaries, comparisons, analysis, and projections integrated across all energy sources. Title: Contingency Reserve 2. This change returns the methodology to the approach used in eGRID2012 and previous editions. Regional Reliability Standard BAL-002-WECC-3 applies to balancing authorities and reserve sharing groups in the Western Interconnection, and it specifies the quantity and types of contingency reserves required to ensure reliability under normal and abnormal conditions. In eGRID2012, the map identified secondary and tertiary subregions; however, starting with eGRID2014, the maps simply indicate areas that fall into more than one eGRID subregion without identifying secondary and tertiary subregions. Arizona-New Mexico-Southern Nevada Power Area (AZ/NM/SNV) Copyright eGRID uses data from the Energy Information Administration (EIA) Forms EIA-860 and EIA-923 and EPAs Clean Air Markets Program Data. document.write(theDate.getFullYear()) Added a hyperlinked table of contents and color coding to the data file. In recent years, there have been several changes to the eGRID content, methodology, and presentation of data. The California Independent System Operator (CAISO) is the largest of about 38 balancing authorities in the western interconnection coordinating council (WECC), handling an estimated 35 percent of the electric load in the west. In 2017, EPA published the first set of AVERT-generated regional and national emission factors. Power Supply Adequacy Consistent with the requirement to maintain operating reserves as defined by WECC and NERC operating policies, WECC conducts, on a seasonal basis, an assessment of generating reserve margins and transmission limitations between load and resource areas as well as probabilities of supplying expected load levels, accounting for uncertainties. The machine-readable files are formatted to allow researchers, regulators, and application developers to more easily access and analyze data. Mercury emissions (when available) are included at the unit-level. Florida Reliability Coordinating Council, Inc. HQT. Air Trends Reportsare EPA's "report card" on the status of air quality and air pollutant emissions. More information about the plant assignment methodology can be found in section 3.4.2 of the Technical Guide. About - Western Energy Imbalance Market For example, the Balancing Authorities actions may include: As defined in the NERC Glossary. For example, the Intermountain Power Project plant is assigned to the CAMX subregion, yet this plant is located in Utah. Electric Reliability Council of Texas, Inc. FRCC. (30.37 KB, 1/30/23) NERC provides industry-wide perspective and oversight, and the Regional Entities have unique features and activities that serve the needs of their regional constituents while ensuring that industry follows NERC Reliability Standards. In Ihrem Browser ist Javascript deaktiviert, wird allerdings zur Darstellung unserer Seite bentigt. This usually occurs near the borders of two subregions. eGRID Code Lookup (xlsx) Output emission rates are reported pounds per megawatt-hour (lb/MWh). Reports are published annually, about ten months after year-end. The WECC is located in the west of Berlin, close to Tegel Airport, to Messe Berlin and the government quarter. %%EOF Non-BA entities may designate reporting contacts in their organizations. Consolidated Balancing Authority - Southwest Power Pool - SPP (3.06 MB, 02/15/2023) Find local businesses, view maps and get driving directions in Google Maps. Regional energy information including dashboards, maps, data, and analyses. Big Data Keeps the Lights On - Esri States and local governments rely on eGRID data for electricity labeling (environmental disclosure programs), emission inventories, and registries as well as for efforts to analyze air emissions from the electric power sector. 2013. Secure .gov websites use HTTPS Within EPA, eGRID data are used by the following applications and programs:Power Profiler, Center for Corporate Climate Leadership, Portfolio Manager, theHousehold Greenhouse Gas Emissions Calculator, theGreenhouse Gas Equivalencies Calculator, and Power Plants and Neighboring Communities. CH4/GWh) for eGRID2010 and eGRID2012 at the subregion-level and also presents the eGRID2014 CH4 output emission rates for comparison. The supporting documentation name was changed from Technical Support Document (TSD) to Technical Guide. theHousehold Greenhouse Gas Emissions Calculator, theGreenhouse Gas Equivalencies Calculator, Greenhouse Gas Emissions for Electric and Plug-in Hybrid Electric Vehicles, Combined Heat and Power and Emissions Savings Calculator, Distributed National Carbon Sequestration Database and Geographic Information System (NATCARB), PJM Interconnections Generation Attribute Tracking System (GATS), EPAs Mandatory Rule on the Reporting of Greenhouse Gases (40 CFR Part 98). PDF California The NERC regions ASCC in Alaska and HICC in Hawaii are no longer included in the EIA-860 Plant file and therefore not included in eGRID2020. eGRID provides an estimate expressed as a percent of generation for the United States, each NERC interconnection (i.e., Eastern, Western, and ERCOT), Alaska, and Hawaii. Number: . Avangrid Renewables notified FERC on April 12 that it is terminating its wind balancing tariff as it prepares to launch its own generation-only balancing authority area (BAA), expected to be operational on June 1, 2018 [ER18-1358]. There are a few cases where the emissions rates decreased. For ongoing work, the best practice is to apply the most recent factors available at the time. Emissions & Generation Resource Integrated Database (eGRID), 2021 Washington, DC: Office of Atmospheric Protection, Clean Air Markets Division. Synchrophasor Data, Operating Reliability Data, Remedial Action Scheme Data, and Transmission Network Model Data, whether or BANC - Balancing Authority of Northern California BCHA - British Columbia Hydro Authority BPAT- Bonneville Power Administration - Transmission . Assets in balancing authority Avangrid - AVRN - WECC Power & Gas The Balancing Authority of Northern California (BANC) is a Joint Powers Authority (JPA) consisting of the Sacramento Municipal Utility District (SMUD), Modesto Irrigation District (MID), Roseville Electric, Redding Electric Utility (REU), Trinity Public Utility District (TPUD) and the City of Shasta Lake as its founding Members. Heat input and emissions values used to adjust combined heat and power (CHP) plants and biomass plants are added to the plant-level. BANC.org - Home Veronica.Whitesmith@PacifiCorp.com. Similarly, WECCs mission today is to: Northwest Power Pool Area (NWPP) What other emissions data are available from EPA? Whenever you switch on an electrical appliance, chances are you are contributing to air pollution and greenhouse gas emissions. A balancing authority is responsible for operating a transmission control area. Power Dispatcher III - BA Job Redmond Washington USA,Energy/Power California ISO - RC West EPA estimates that the GGL is about 5% of the electricity that is transmitted and distributed annually in the United States. Credible Source of Interconnection-Wide Information- WECC provides training, education and information on key functions related to mandatory standards and compliance, as well as data, analysis and studies relating to transmission system planning, and renewable integration. It is managed by 37 Balancing Authorities (BAs) of various ownership structures . The subregion emission rates most accurately represent the actual electricity used by consumers by limiting the import and export of electricity within an aggregated area. In addition to the data categories identified in the February 18 data request, we propose to direct that NERC and WECC provide: (1) The DCS performance--as described in request (1) in the paragraph above--on a balancing authority basis; and (2) the hourly amount of contingency reserve and the fraction of that contingency reserve that is . The ERO Enterprise now encompasses six regional organizations of similar size and complexity.